03How we deliver

A fixed six-stage route from your process layout to a design package

  1. 01

    Design basis

    Site data, soil report, seismic zone, exposure condition, water table and load philosophy are fixed in writing. Codes, material grades, cover and crack-width limits are agreed before any analysis begins.

  2. 02

    Mechanical GAD → Civil GAD

  3. 03

    Analysis & design

    Analysis models and parametric design workbooks built on HYDRO PRO, our in-house design suite.

  4. 04

    RC detailing & BBS

    Bar bending schedules with cutting lengths.

  5. 05

    Submission & proof check

    Design report and drawings issued in departmental format. We respond to third-party proof-checker and departmental comments through to clearance.

  6. 06

    Site support

    Query resolution during execution, revision of drawings against site constraints, and issue of as-built marked-up sets on request.

Indicative turnaround

Dates you can plan a bid around

DeliverableTypical issue time
Pre-bid sizing, footprint & budgetary quantities3 – 5 working days
Mechanical GAD to civil GAD (single unit)5 – 7 working days
Complete structural design + RC drawings + BBS (single unit)2 – 2.5 weeks
Full plant package (WTP / STP, all civil units)By agreed programme

Indicative only; confirmed against scope, data availability and drawing count at the time of award.

04Our in-house design suite

HYDRO PRO

Rather than assembling each job from scratch, we run our design work on HYDRO PRO, a suite built in-house over the years from our own project library. It is what lets us hold short delivery dates without losing consistency between one job and the next.

Every output sheet carries the governing code clause against the result, so what we issue is ready for departmental and third-party checking as it stands.

  • Parametric sizing of treatment units, reservoirs and storage structures straight from capacity input
  • Hydraulic analysis of water supply, sewerage and storm networks, rising mains and gravity mains
  • Hydraulic profile generation across the full unit train of a plant
  • Structural design of liquid-retaining, framed and foundation structures with built-in code checks
  • Reinforcement and concrete quantity abstracts, and bar bending schedules with cutting lengths
  • Instant re-run when capacity, level or soil data changes — options compared in hours, not days

Indian codes — primary practice

Codes and standards we design to

IS 456Plain and reinforced concrete
IS 3370 (2021)Liquid retaining structures
IS 800General construction in steel
IS 1893 / IS 13920Seismic design and ductile detailing
SP 34 / IS 2502Detailing and bar bending
IS 875Loads on buildings and structures
CPHEEOWater Supply & Sewerage Manuals
IS 1904 / IS 2911Foundations and piles

Checking & quality assurance

Checked before it leaves the office

  • Every model is independently verified before its results are used for design.
  • Liquid-retaining units are checked for crack width, flotation, sliding and overturning as a standing part of the design, not on request.
  • Drawings are cross-checked against the calculation before issue.
  • Design documents are prepared to stand up to independent third-party proof checking, including by premier institutes.

Let’s discuss your project

Send us the drawings, the tender scope or simply the brief, and we will revert with a scope note, a delivery schedule and a fee proposal.